Products 

PR10 – low-cost paperless recorder

PR10 -  paperless recorder
Specification

 
Product position Low-cost one, good for replacing 6-dotting chart
recorders, and 1, 2, 3 pen recorders
Input numbers3, 6 channels
True universal inputsThermocouples: J, K, T, E, B, R, S, N, L, U, P, W5, W3, LR, A1, A2, A3, M
RTD: Pt50, Pt100, Pt200, Pt500, Pt1000 (α=0.00385), Pt50, Pt100 (α=0.00391), Cu10 (α=0.00427), Cu50, Cu100(α=0.00426, 0.00428), Ni100, Ni200, Ni500, JPt50, JPt100, JPt200, JPt500, JPt1000 (α=0.003916) Ni1000 (α=0.00617) mA, V, mV
The fastest sampling rate To reach 100 msec / dot, default setting at 1 sec / dot
Math, External channels, Batch,
Custom display, FDA 21 CFR part 11
Math in standard version, others in Plus versions
Display4.3" TFT wide touch screen
Resolution480 x 272
MTFB backlight at 25°C30,000 hrs
BacklightLED
Screen saver, EmailYes
A faster CPUARM Cortex-A8, 1Ghz
Internal flash memory 256 MB
RAM 256 MB
EthernetModbus TCP/IP
RS-232/422/485 Otional RS-232 or RS-422/485 Modbus RTU
SD card slot, USB host x 2 Standard, one USB in the front, another USB in the back
Pulse input Optional DI card offering either logic or high frequency pulse counter
START / STOP key To start / stop record and to turn off the display only, not recorder itself so that a quick start possible
Calibration correction On-site calibration possible, or using handy features of Offset and Gain for correction
Multilingual Convenient for local users by offering 19 languages including English, Japanese, Danish, Italian, Polish, Russian, Dutch, Korean, Thai, Turkish, Portuguese, Chinese (simplied, traditional), French, German, Spanish, Swedish, Brazil Portuguese, Czech, other languages negotiable
PC software historical viewer+ configuration Standard
Extensive software data acquisition studio Optional real-time monitoring
Power supply90-250VAC or 11-36VDC
Outer dimensions (W x H x L mm)144 x 144 x189
Shorter mounting depth (mm)171
DIN panel cutout (W x H mm) 137 x 137
ProtectionIP65 front, IP20 rear
Operating temperature0°C to 50°C
Storage temperature-30°C to 70°C
Safety standardsCE, cULus, RoHS

Ordering Code

PR10 -
1 2 3 4 5 6 7
 
1 InputPR1003 (3 analog inputs) 
               0: none
               6: 3 relays + 3 DI 
PR1006 (6 analog inputs) 

               0: none
               1: 6 relays
               3: 6 DI
               6: 3 relays + 3 DI
               7: 6 relays + 6 DI
2 Power A: 90-250 VAC, 50/60 Hz
D: 11-36 VDC
3 Communication 0: Standard Ethernet
1: Ethernet + RS232
2: Ethernet + RS-422/485
4 Firmware 0: Standard version with mathematics
1: Plus version 1 external channels, batch & FDA 21 CFR part 11
2: Plus version 2 with custom edited display, an editing software Panel Studio to be supplied
3: Plus version 3 including Plus version 1+2 above
5 PC software 1: Free basic software of Historical Viewer & Configuration
2: Extensive software Data Acquisition Studio (RealTime Viewer + Historical Viewer + Configuration)
6 Mounting types, power cord & switch 0: Panel mount, no power cord, no power switch
1: Panel mount, no power cord, power switch
2: Portable, UL & CSA power cord, power switch
3: Portable, VDE power cord, power switch
4: Portable, SAA power cord, power switch
5: Portable, BS power cord, power switch
6: Portable, no power cord, power switch
7: Panel mount, UL & CSA power cord,power switch
8: Panel mount, VDE power cord, power switch
9: Panel mount, SAA power cord, power switch
A: Panel mount, BS power cord, power switch
7 Special options00: none
S1: 16G SD card
S2: 32G SD card
10: PID card
11: PID card+16G SD card
12: PID card+32G SD card
    ※NOTE※
  • DI - digital inputs
  • Process control card ordering code needs to be chosen after Special options 10,11,12 been selected
PC201 -
A B C D
A: Output 1 0: None
1: Relay 2A/240VAC
2: Pulse voltage to drive SSR, 5V/30mA
3: Isolated 4-20mA/0-20mA (OM95-3)
4: Isolated 1-5V/0-5V (OM95-4)
5: Isolated 0-10V (OM95-5)
6: Triac output 1A/240VAC,SSR
C: Pulse voltage to drive SSR, 14V/40mA (OM94-7)
B: Output 2 0: None
1: Relay 2A/240VAC
2: Pulse voltage to drive SSR, 5V/30mA
3: Isolated 4-20mA/0-20mA (OM95-3)
4: Isolated 1-5V/0-5V (OM95-4)
5: Isolated 0-10V (OM95-5)
6: Triac output 1A/240VAC,SSR
7: Isolated 20VDC/25mA power supply (DC94-1)
8: Isolated 12VDC/40mA power supply (DC94-2)
9: Isolated 5VDC/80mA power supply (DC94-3)
C: Pulse voltage to drive SSR, 14V/40mA (OM94-7)
C: Alarm 1 0: None
1: Form C relay 2A/240VAC
D: Alarm 2 0: None
1: Form A relay 2A/240VAC

Documentation

Catalog LFPR ( 3.2MB / 9pages )
User Manual UMFPR01E (10.1 MB / 348pages )
UMPC201 (1.58 MB / 113pages)
Self training Flash Format
Firmware RECORDER_PV210
Software Historical Viewer
  Panel Studio